INSTITUTIONS
The range of our institution projects include Healthcare, Sports Venues and Museums and Theaters.
![]()
Healthcare facilities can take advantage of Post-Tensioning’s versatility. Future penetrations can be located with ground-penetrating radar.

MARIANJOY HOSPITAL
Project Name: Marianjoy Rehabilition Hospital
Location: Wheaton, IL
Contractor: Tetratech
PT Quantity: 330,000 feet
Facts: The project had a complex pattern of tendons in the flat-plate system. Most of the tendons were curved due to the column layout and building shape.
![]()
Post-Tensioned Concrete can be selected for sports arenas for its superior durability, quick construction time and capability to enable a column-free design that offers better lighting. AMSYSCO has worked on many structures related to the entertainment industry.
Project Name: Minnesota Twins Ballpark (Target Field)
Location: Minneapolis, MN
Contractor: M.A. Mortenson
PT Quantity: 750,000 feet
Facts: The open-air, 1 million-square-foot ballpark holds seating for 40,000 fans. PT was used in the beams and girders that supported seating and office areas.
> View PTI presentation by Neel Khosa
> Read article in ‘Structural Engineering & Design’ magazine

EDWARD JONES STADIUM
Project Name: Edward Jones Stadium
Location: St. Louis, MO
Contractor: Alberici Construction
PT Quantity: 800,000 feet
Facts: The project incorporated Post-Tensioned raker beams which were cast at approximately 45-degree angles. These beams supported the seating floor. The raker beams had PT tendons with rather unusual profile. The accuracy of the shop drawings became critical to the project’s success.
![]()
Post-Tensioning can solve unique structural and architectural problems with the construction of theaters and museums. High-strength PT are used to support heavy live-load and dead-loads.

GUTHRIE THEATRE
Project Name: New Guthrie Theatre & Garage
Location: Minneapolis, MN
Contractor: McGough Construction
PT Quantity: 80,000 feet in theatre and 1.0 million feet in the garage
Facts: The Guthrie Theatre won the 2008 PTI Award of Excellence Project of the Year. The framing system for the theatre consisted of an 8″ thick sloping Post-Tensioned slab supported by a radial/circular network of PT beams and cantilevered PT girders on five tiers. The complex design solved requirements for heavy-loading and column-free areas. The Post-Tensioned Garage has 1000 parking spaces.