Yearly Archives: 2011

Video : Applying paint mark for Tendon Elongation

This short clip shows how to apply paint-marks prior to stressing of post-tension tendons. It’s recommended to use a straight-edge, metal to help with elongation measurements. Refer to the Post-Tensioning Institute’s “Field Procedures Manual for Unbonded Single-Strand Tendons” Chapter 7 … Continue reading

Share
Posted in Field Issues, Video | Tagged , , , | Comments Off on Video : Applying paint mark for Tendon Elongation

How do I know if my Post-Tensioning Tendons have been stressed?

As a post-tensioning inspector or installer, have you ever been in a situation whether you are unsure whether some PT tendons have been stressed? By not having a PT tendon stressed, this could have detrimental effects on the structure. Here … Continue reading

Share
Posted in Field Issues | Tagged , , , , | Comments Off on How do I know if my Post-Tensioning Tendons have been stressed?

PTI 2011 Technical Presentation – Target Field

Presentation by Neel Khosa given during the Post-Tensioning Institute’s 2011 Technical Conference. Topic is about the use of unbonded post-tensioned concrete and stage-stressing PT girders in Target Field stadium, home of the Minnesota Twins MLB team. Minnesota Twins Target Field … Continue reading

Share
Posted in Project Updates | Tagged , | Comments Off on PTI 2011 Technical Presentation – Target Field